| Specification |
|
Item
|
Specification
| |
| Compressor | Type | Gamma 1.6 MPI, Gasoline 2.0 NU MPI, Gasoline 1.6 T-GDI : 6HVx14 Gasoline 1.6 MPI : 6HVe14 |
| Oil type & Capacity | FD46XG (IDEMITSU) 100 ± 10 g | |
| Pulley type | 6PK-TYPE | |
| Displacement | 145 cc/rev | |
| Expansion valve | Type | Block type |
| Refrigerant | Type | R - 134a, R-1234yf |
| Capacity | 500 ± 25 g | |
|
Item
|
Specification
| |
| Fresh and recirculation | Operating method | Actuator |
| Blower | Type | Sirocco pan |
| Speed step | Auto + 8 speed (Automatic), 1 - 4 speed (Manual) | |
| Speed control | Power mosfet (Automatic), Resistor (Manual) | |
| Air filter | Type | Particle filter |
|
Item
|
Specification
| |||
| Heater | Type | Fin & Tube type | ||
| Type | Tube - Fin 1Way | |||
| Mode operating method | Actuator | |||
| Temperature operating method | Actuator | |||
| Evaporator | Temperature control type | Evaporator temperature sensor | ||
| Blower singular | A/C Output OFF Temperature | A/C Output ON Temperature | ||
| Manual control | 1 - 2 speed | 1.5°C (34.7°F) | 3.0°C (37.4°F) | |
| 3 - 4 speed | 0.6°C (33.1°F) | 2.1°C (35.8°F) | ||
| Dual control | 1 - 4 speed | 1.5°C (34.7°F) | 3.0°C (37.4°F) | |
| 5 - 6 speed | 1.0°C (33.8°F) | 2.5°C (36.5°F) | ||
| 7 - 8 speed | 0.6°C (33.1°F) | 2.1°C (35.8°F) | ||
| Manufacturer | HVCC (Halla Visteon Climate Control) | |||
|
Items
|
N.m
|
kgf.m
|
lb - ft
|
| Compressor | 20.0 - 32.95 | 2.04 - 3.36 | 14.75 - 24.30 |
| Condenser - Discharge hose | 8.8 - 13.7 | 0.9 - 1.4 | 6.5 - 10.1 |
| Condenser - Liquid tube | |||
| Compressor - Discharge hose | 21.6 - 32.4 | 2.2 - 3.3 | 15.9 - 23.9 |
| Compressor - Suction hose | |||
| Expansion valve - Evaporator | 8.8 - 13.7 | 0.9 - 1.4 | 6.5 - 10.1 |
TroubleshootingProblem Symptoms TableBefore replacing or repairing air conditioning components, first determine if the malfunction is due to the refrigerant charge, air flow or compressor.
Special Service Tools Tool (Number and name) Illustration Use 09977-3R000Disc & hub assembly bolt removerRemoval and installation of disc & hub assembly.
C
Description and operation DescriptionThe mode control actuator is located at the heater unit.It adjusts the position of the mode door by operating the mode control actuator based on the signal of the A/C control unit. Pressing the mode select switch makes the mode control actuator shift in order of Vent → Bi-Level → Floor → Mix.