| Description |
| • | PDW consists of 8 sensors (front : 4 units, rear : 4 units) that are used to detect obstacles and transmit the result in three separate warning levels, the first, second and third to IBU via LIN communication. |
| • | IBU decides the alarm level by the transmitted communication message from the slave sensors, then operates the buzzer or transmits the data for display. |

| Initial mode |
| 1. | System initializing time
|
| 2. | PDW recognizes LID and sets the sensor ID up during initialization. |
| 3. | PDW activates each sensor and then executes the diagnosis after finishing initialization of IPM(IBU). |
| 4. | PDW starting buzzer is normally worked, when sensor does not send an error message and after finishing error diagnosis. |
| 5. | If any failure is received from the any sensors, PDW starting buzzer does not work but the failure alarm is operated for a moment. If you have display option, warning sign is also shown on it.
|
| 6. | IBU memorizes the completed initializing status of sensor. |
| Normal mode |
| 1. | PDW-F : Lin communication starts and keeps the routine after IGN1 ON+D gear + below 10 km/h. PDW-R : Lin communication starts and keeps the routine after IGN1 ON+R gear |
| 2. | After initializing, the routine starts at once without PDW starting warning sound. |
| 3. | Alarms of obstacle consists of 3 level 1,2,3 step and 1,2 alarm sounds intermittently and 3 alarm sounds continuously. 1 level alarm doesn't exist in the front ultrasonic sensor. |
| 4. | In display, the data of each sensor is sent from IBU to display, for example cluster. CAN communication is used for transmission and maximum gateway time is 50ms. |
| 5. | The efficient vehicle speed of PDW operation is under 10Km/h. |
| 6. | Operation doesn't start or stops at gear N, P. |
| Level | Distance range | Allowed range |
| 1 | Front : 61 - 100 cm (24.02 - 39.37 in.) / Rear : 61 - 120 cm (24.02 - 47.2 in.) | ± 15 cm (5.90 in.) |
| 2 | 31 - 60 cm (12.20 - 23.62 in.) | ± 15 cm (5.90 in.) |
| 3 | 0 - 30 cm (0 - 11.81 in) | ± 10 cm (3.94 in.) |

Component Location1. Integrated body control unit (IBU) 2. Ultrasonic sensor
Description and operation Description 1.The photo sensor is located at the center of the defrost nozzles.2.The photo sensor contains a photovoltaic (sensitive to sunlight) diode. The solar radiation received by its light receiving portion, generates an electromotive force in proportion to the amount of radiation received which is transferred to
Inspection1.Check for resistance between terminals in each switch position (LH).[LH : Audio + Hands free] Switch Resistance (±5%) SEEK Up430 ΩSEEK Down1.11 kΩMODE2.11 kΩMUTE3.11 kΩVolume (+)4.