| Troubleshooting |
|
Symptom
|
Suspect area
|
Remedy
|
| Charging warning indicator does not light with ignition switch "ON" and engine off. | Fuse blown | Check fuses |
| Light burned out | Replace light | |
| Wiring connection loose | Tighten loose connection | |
| Electronic voltage regulator | Disconnect the voltage regulator to see if light turns off. If light turns off, replace voltage regulator. | |
| Charging warning indicator does not go out with engine running. (Battery requires frequent recharging) | Drive belt loose or worn | Adjust belt tension or replace belt |
| Battery cable loose, corroded or worn | Inspect cable connection, repair or replace cable | |
| Electronic voltage regulator or alternator | Disconnect the voltage regulator or alternator to see if light turns off. If light turns off, replace voltage regulator. | |
| Wiring | Repair or replace wiring | |
| Overcharge | Electronic voltage regulator | Disconnect the voltage regulator to see if light turns off. If light turns off, replace voltage regulator. |
| Voltage sensing wire | Repair or replace wiring | |
| Discharge | Drive belt loose or worn | Adjust belt tension or replace belt |
| Wiring connection loose or short circuit | Inspect wiring connection, repair or replace wiring | |
| Electronic voltage regulator or alternator | Disconnect the voltage regulator or alternator to see if light turns off. If light turns off, replace voltage regulator. | |
| Poor grounding | Inspect ground or repair | |
| Worn battery | Replace battery |
DescriptionThe charging system included a battery, an alternator with a built-in regulator, and the charging indicator light and wire.The Alternator has eight built-in diodes, each rectifying AC current to DC current.
InspectionInspecion Item• Battery efficiency inspection• Battery voltage inspection• Charging voltage insptection• General inspection• Terminal tightening state inspection• Engine/ transaxle ground state inspection• Wiring hareness ground state inspection• Electrical Specified Value Inspection• Vehicle parasitic current inspection • Inspect the battery capacityBattery Efficiency Inspection • Check that the battery cables are connected to the correct terminals.
Description and OperationWireless Power Charger SystemDuring ACC or IG ON, battery voltage is supplied to the wireless power charger system to transmit an output of 5 W to mobile phone. Mobile phones certified with the wireless charging standard WPC (Qi 1.
Refrigerant System Service Basics (R-134a)Refrigerant Recovery Use only service equipment that is U.L-listed and is certified to meet the requirements of SAE J2210 to remove HFC-134a(R-134a) from the air conditioning system. • Air conditioning refrigerant or lubricant vapor can irritate your eyes, nose, or