| Specifications |
|
Item
|
Specification
| |
| Ultrasonic sensor | Voltage rating | DC 12 V |
| Detecting range | 11.8 - 47.2 in. (30 - 120 cm) | |
| Operation voltage | DC 9 - 16 V | |
| Operation current | MAX 350 mA | |
| Operation temperature | -22 - 176°F (-30 - 80°C) | |
| Operation frequency | 48 ± 5 KHz | |
| Number of sensors | 8 units | |
Component Location1. Integrated body control unit (IBU) 2. Ultrasonic sensor
Schematic diagrams Circuit Diagram Repair procedures Removal1.Remove the bumper cover.(Refer to Body - "Front Bumper Cover")(Refer to Body - "Rear Bumper Cover")2.
S
TroubleshootingDiagnosis with Diagnostic tool1.In the body electrical system, failure can be quickly diagnosed by using the vehicle diagnostic system (Diagnostic tool).The diagnostic system (Diagnostic tool) provides the following information.1)Fault Code Searching : Checking failure and code number (DTC)2)Data Analysis : Checking the system input/