Repair procedures Removal and Installation1.Disconnect the battery negative terminal.2.Disconnect the oil pressure control solenoid valve connector (A).
Components and components location Components1. Air cleaner cover2. Air cleaner element3. Air cleaner body & air duct5. Air intake hose Repair procedures Removal and InstallationAir Cleaner Assembly.
Components and components location Components Location[General type]1. Condenser[N Line]1. Condenser Repair procedures Inspection1.Check the condenser fins for clogging and damage. If clogged, clean them with water, and blow them with compressed air.
Description and operation DescriptionIt is installed to the DATC and adjusts the fan rpm by precisely controlling the voltage applied to the blower motor. Repair procedures Inspection1.Manually operate the control switch and measure the voltage of the blower motor.