Repair procedures Removal and Installation1.Disconnect the battery negative terminal.2.Disconnect the oil pressure control solenoid valve connector (A).
Components and components location Components1. Air cleaner cover2. Air cleaner element3. Air cleaner body & air duct5. Air intake hose Repair procedures Removal and InstallationAir Cleaner Assembly.
Description and operation DescriptionThe temperature control actuator is located at the heater unit. It regulates the temperature by the procedure as follows. The signal from the control unit adjusts the position of the temperature door by operating the temperature switch.
Repair procedures Inspection1.Measure the resistance between the terminals.2.The measured resistance is not within specification, the blower resistor must be replaced. (After removing the resistor)Replacement1.Disconnect the negative (-) battery terminal.