Description and operation DescriptionThe intake actuator is located at the blower unit. It regulates the intake door by a signal from the control unit.
Components and components location Components[This illustration shows the LHD type. RHD type is symmetrical.][Connector A] Pin No Function Pin No Function 1Low (Register specifications)4Middle Low (Register specifications)2Common (Register specifications)5Middle High (Register specifications)3Ground (Register specifications)6High (Register specifications)[Connector B] Pin No Function Pin No Function 1Battery (+)21IGN22ISG B+22IGN13ILL+ (TAIL)23Blower IS (PWM specifications)4Sensor REF (+5V)24-5Mode control actuator (Feedback)25-6Temperature control actuator (Feedback)26-7Intake actuator (Feedback)27Blower Max.
Description and operation Description 1.The photo sensor is located at the center of the defrost nozzles.2.The photo sensor contains a photovoltaic (sensitive to sunlight) diode. The solar radiation received by its light receiving portion, generates an electromotive force in proportion to the amount of radiation received which is transferred to
Description and operation DescriptionThe ambient temperature sensor is located at the front of the condenser and detects ambient air temperature. It is a negative type thermistor; resistance will increase with lower temperature, and decrease with higher temperature.